Optimizing Desalter Performance

Posted by Margaret Bletsch

Mar 11, 2019 4:44:31 PM

Optimizing Desalter Performance is Just One of Tracerco's Specialties We Proudly Provide.

Desalter vessels are a refinery’s first line of defense to reduce the amount of unwanted salts present in the feed inventory. Prior to crude oil entering a refinery processing stream it undergoes a water washing stage where the water used during this process is separated using Desalter vessels. In these vessels the oil and water mixture separate from each other using gravity and high voltage coalescing plates. The water phase contains the washed salts as well as other suspended solids. Desalting and separation prevents water and salts from entering the crude unit furnaces, distillation towers and other downstream equipment. Salts, sediment, and other solids will foul the process and can undergo chemical change to produce corrosive chemicals that cause damage to process metallurgy. It is therefore important to efficiently separate wastewater from crude feedstock within the Desalter vessels.

Tracerco Tru-Scan™ technology provides you detailed data on where the oil/water interface level is, determines if there is a significant “rag” or emulsion layer or detects how many solids are built up in the bottom of the Desalter. In addition to performing these applications our advanced tracer studies are used to provide residence times of the oil and water phases and distribution within the vessel. Further to our scanning and tracer technologies that can aid plant personnel in optimizing your process, our award winning Tracerco Profiler™ HTX instrument provides accurate phase measurement including oil, emulsion (rag), water and solids/sludge in real time. The installation of the Tracerco Profiler™ HTX can eliminate unplanned Desalter shutdowns, reduce chemical usage, increase fluid throughput and provide the capability to handle more challenging crude blends.

Read more to learn how Tracerco helped our customer determine what was actually happening within their Desalter.

Read More

Topics: desalting, Flow distribution, desalter optimization, desalter, desalter maldistribution, distribution study

Tracerco Insight Vol8 Ed2

Posted by Margaret Bletsch

Feb 28, 2019 9:09:35 PM

Tracerco Insight Vol. 8 Ed. 2 newsletter is now available.

The Tracerco Insight newsletter featuring some of our latest case studies illustrating how Tracerco was able to provide our customers the necessary data that allowed the operations staff to make informed decisions for troubleshooting and optimising their process. Read more to see what's inside the latest issue.

This issue contains the following articles:
  • Optimizing Desalter Performance Is Just One of Tracerco's Specialties We Proudly Provide. 
  • Crude Vacuum Tower Wash Bed Optimization.
  • Application Note - ThruVision™
  • Manage and Control Your Turnaround Costs to Avoid Possible Surprises.
  • New Product Announcement: PED-ER and PED-ER+

Read more on how to download the latest issue.

Read More

Topics: nucleonic instrumentation, Tru-Scan, process diagnostics technologies, gamma scan, monitor wash bed coking, tracer technology, Tracer Study, catalyst bed wash, desalter optimization, wash bed optimization, manage turnaround costs, Depropanizer scan tray damage, desalter, Tracerco Profiler, crude vacuum tower, turnaround critical path project, pre-turnaround scans

Oil and Gas Comment and News 

Tracerco's news and comment on measurement and diagnostics in Oil & Gas and processing industries

Tracerco brings comment, news, how tos and more on their blog. Sign up for regular notifications of new posts. 

Subscribe to Email Updates

Recent Posts

Posts by Topic

see all

Contact us today or email us at tracerco@tracerco.com

  • We measure the unmeasurable
  • access the inaccessible
  • and help solve the impossible